Analysis of Wind Behavior in Natural Ventilation and Reduction of Energy Consumption in Residential Building Based on Vernacular Architecture: A Case Study of Effects of Dimensions and Layout of Opening on Natural Ventilation in Amol City, Iran

Document Type : Original Article

Authors

1 M.A. of Architecture, Faculty of Art and Architecture, Islamic Azad University, Science and Research Branch, Tehran, Iran

2 Assistant Professor of Architecture, Department of Architecture, Faculty of Art and Architecture, Islamic Azad University, East Tehran Branch, Tehran, Iran.

Abstract

The increased average of non-renewable energy consumption in the residential sector and not using the passive techniques, which are often based on the vernacular architecture concepts and principles and climate, have led to energy waste and increased costs. Due to humidity and excessive heat in summer at noon, Amol exceeds the thermal comfort and needs natural ventilation. The current study aims to study the effect of dimensions and layout of the opening on the natural ventilation and reduction of energy consumption. First, reviewing the research background, natural ventilation was determined as the main component of the building design in this climate, and the operational principles of the stated component were extracted using Climate Consultant. Among the operational principles, the value of the opening area was determined as the main criterion of the climate design using the AHP method. With simulating a one-story residential building with an area of 75 square meters in Amol’s climate in Envi-Met software and inputting climate information obtained from Climate Consultant analysis in Envi-met, the wind direction was north and north-western. The building understudy was simulated in Design Builder software. By comparing the window to surface percentage ratio and annual energy consumption, the ratio of 30% with the minimum energy consumption equivalent to 6839.87 kwh was considered the criterion for studying the opening effect. Windows of the residential building were considered as three parts to study the effect of the opening dimensions. In northern and southern sides where one-third of the window was closed, the minimum energy consumption value as the total of thermal and cooling loads was 7298.93 kwh, indicating the effects of the dimensions of the opening in the natural ventilation of the building in the humid and moderate climate.

Keywords


Bergman, D. (2017). Practical Guide to Sustainable Design, (Rahnama. H, Trans.). Tehran, First and last Publications, 2(1), 43.
Foroughian, S., & Taheri ShahrAyini, M. (2015). Investigating and Simulating the Effects of Dimensions, Orientation and Window Type on Optimization of Energy Consumption in Buildings (Sample Simulation in Mashhad), International Conference on Architecture, Urban Development, Civil, Art and Environment; Future Horizons, Looking Back, 4-6, Tehran. https://civilica.com/doc/607628
Ghiasi, M.I., Golkar , M.A.A., & Hajizade, A. (2015). Intelligent Energy Management for Zero Energy Buildings including Photovoltaic. Fuel Cell Power Sources and Plug-in Electric Vehicles, 4(1), 25. http://www.sid.ir/fa/journal/viewpaper.aspx?id=250723
Hejazizdadeh, Z., & Karbalaei Dori, A. (2015). Thermal Comfort in Iran. Geography Society of Iran, 13(46), 21. https://www.magiran.com/paper/1490749
Kasmaei, M. (2012). Climate and Architecture, Esfehan, Soil Publications, 80.
Mahmoodi Pati, F., Nikpoor, A., & Mahmoudi, M. (2016). The Impact of Climate Properties on the Design of Traditional Homes in Amol with a Sustainable Architecture Approach, The first international conference and the second national conference on identity-oriented architecture and urbanization, 5, Mashhad. https://civilica.com/doc/593058/
Pourdihimi, Sh. (2011). Climatic Language in Sustainable Environment Design, Tehran, Shahid Beheshti University, 6(1), 68.
Rasti, S., & Roshan, M. (2017). Evaluation of Energy Consumption Reduction in Residential Building by Optimal Orientation and Population Percentage in Anzali City. Renewable Energy, 4(2), 91. https://www.jrenew.ir/article_59908.html
Sohrabi, H., Ghadimi, M., & Haji Mollaali Kani, A. (2018). Sensitivity Analysis of Energy Consumption with Respect to Window to Wall Ratio in a Residential Building, in Temperate and Humid Climates, (Case Study: Ramsar City) , First National Conference on Advanced Technologies in Engineering and Environment, Tehran, Sharif University of Technology,1(1), 28. https://civilica.com/doc/848761./
Taher Tolou Del, M.S., & Aminifar, Z. (2016). Investigating Environmental Comfort Variables with Emphasis on Improving the Quality of Learning in the Educational Environment. Journal of Education Technology, 1, 1-9. https://www.sid.ir/fa/journal/viewpaper.aspx?id=286216 
Watson, D., & Lebz, K. (2013). Climatic design: energy - efficient building principles and practices,  (V. Ghobadian, & M. Mahdavi, Trans.). Tehran, University of Tehran Publications, 12.
Zakeri, M.H., Gorji, M., & Hossein Zade, M. (2014). Zero Energy House Case Study: Ghaemshahr Residential Building, 4th International Conference on New Approaches to Energy Conservation , 2, Tehran. https://civilica.com/doc/494269/